Radiant Heat USA Rotating Header Image

Grundfos Pump

Grundfos Alpha Pump Supplying High Energy Efficiency with Excellent Performance

Alpha Grundfos Pump

Alpha Pump Chart

The Grundfos Alpha is energy efficient next generation circulator pump introduced by Grundfos. By installing these hi-tech pumps which are incorporated with robust magnet motor set up it would be now possible to reduce power consumption by almost 50%. The circulator pump acclimatizes to variable demands of heating systems without forfeiting comfort. With powerful inbuilt AUTOADAPT feature, this pump can analyze the heating system on its own and adjust accordingly in order to meet all sorts of heating demands to fullest.

This is an excellent circulation pump integrated with numerous outstanding features. The unit is incorporated with differential pressure control that enables adjusting the performance of pump according to the requirements of actual system. The motor integrated within this system is based on advance permanent magnet technological norms due to which it can supply high efficiency by utilizing very low level of power. In addition to this, The Grundfos Alpha is inclusive of automatic night time performing system. It also holds clear, readable display which shows the amount of actual power being consumed by the system in Watt. This powerful unit is energy optimized and certified ‘A’. The level ‘A’ certification clearly demonstrates that the system holds best energy efficiency capability

Grundfos UPS43-44FC 3-Speed Circulator Pump

Grundfos UPS43-44FC Pump

Click on image to enlarge

Grundfos UPS43-44FC PumpGrundfos UPS43-44FC Pump
GrundfosBrand: Grundfos

SKU #: 52722514


Availability: In Stock
Usually ships: within 1 business day
Qty Price
$274.00 / each
Product Description:


Grundfos UPS43-44FC 3-Speed Cast Iron Circulator Pump with Check Valve.

Features:

  • Built-in motor protection for longer life and better performance;
  • Integral Check Valve;
  • Whisper-quiet operation for sound sensitive installations;
  • Includes (2) Gaskets (O-rings).

Circulation pumps UPS 43 – three-speed pumps with \ “Glandless \” intended for use in heating, cooling and air conditioning, a special performance of pumps UPS 43 operates in the hot water supply systems. Pumps UPS 43 series should be protected from overheating. To do this you must purchase a separate switching module, which in turn produces svuyu off the pump in the event of malfunctions.Technical Specifications of Grundfos UPS43-44FC:

  • Voltage: 115V;
  • Amperage at Speed 1: 1.4 Amps;
  • Amperage at Speed 2: 1.7 Amps;
  • Amperage at Speed 3: 1.8 Amps;
  • Watts at Speed 1: 157W;
  • Watts at Speed 2: 189W;
  • Watts at Speed 3: 203W;
  • Hertz: 60 Hz;
  • Phase: 1;
  • Max Pressure: 145 psi;
  • Max. Temperature: 230F;
  • Min. Temperature: 36F;
  • Flow Range: 0-63 GPM;
  • Head Range: 0-14 ft;
  • Horse Power: 1/6HP;
  • Body: Cast Iron;
  • Connections: Flanged, 3/4″, 1″, 1-1/4″, 1-1/2″;
  • Grundfos UPS43-44FC 3-Speed Circulator Pump

Grundfos UPS26-99FC 3-Speed Circulator Pump

Grundfos UPS26-99FC Pump

Click on image to enlarge

Grundfos UPS26-99FC Pump Side ViewGrundfos UPS26-99FC Pump in Box
GrundfosBrand: Grundfos

Grundfos UPS26-99FC 3-Speed Circulator Pump -  Grundfos Pump UPS 99 series are equipped with an electric motor with wet rotor and stator is protected, without seals, with two O-rings.

SKU #: 52722512


Availability: In Stock
Usually ships: within 1 business day
Qty Price
$215.95 / each
Product Description:


The Grundfos UPS26-99FC is a 3-speed circulator pump with built-in flow check. This model features pre-programmed usage times that help save power and incorporates an automatic resetting thermal protection that assures motor safety and longer life.

Features:

  • Built-in motor protection for longer life and better performance.
  • Suitable for a wide range of applications, including radiant heating, hydronic heating, fan coil heating, solar and other system types.
  • Whisper-quiet operation for sound sensitive installations.
  • Includes (2) Gaskets (O-rings).
  • UL/CSA listed.

Applications:

  • Closed loop radiant heating & snow melting systems.
  • Baseboard/Radiator/Fan coil heating and other hydronic heating applications.

Technical Specifications:

  • Voltage: 115V;
  • Amperage at Speed 1: 1.3 Amps;
  • Amperage at Speed 2: 1.5 Amps;
  • Amperage at Speed 3: 1.8 Amps;
  • Hertz: 60 Hz;
  • Phase: 1;
  • Watts at Speed 1: 150W;
  • Watts at Speed 2: 179W;
  • Watts at Speed 3: 197W;
  • Max Pressure: 145 psi;
  • Max Temperature: 230F;
  • Min Temperature: 36F;
  • Flow Range: 0-33 GPM;
  • Head Range: 0-29 ft;
  • Horse Power: 1/6HP;
  • Body: Cast Iron;
  • Connections: Flanged, 1/2″, 3/4″, 1”, 1-1/4”;

Pumps and mixing pad

Pump-and-mixing unit Taco RMB-1 Radiant Mixing Block intended for installation on a comb floor heating, stainless steel, it regulates the temperature of the filing in the circuit radiator heating. Pump-and-mixing unit supports temperature coolant supply constant by mixing return water with the help of a three-way valve and a thermostat with overhead sensor.

* Setting range: 20 … 50 P
* Max. Working temperature: 90C (in the primary and secondary circuit)
* Max. pressure: 6 bar
* Max. differential pressure: 0,75 bar
* Kvs: 4,0
* Construction length: 315 mm

The circulation of coolant is carried out using a pump with electronic regulation. To protect the surface heating from the high temperature, oil-mixing unit is also equipped with an electric controller with overhead sensor.

The advantage of oil-mixing unit Taco RMB-1 Radiant Mixing Block is the ability to regulate the temperature of the filing of combined systems with radiators and panel heating.

Mounted and pressure-tested unit includes: Grundfos Alpha Pump with electronically controlled, three-way distribution valve, overhead valve with a sensor. Electric bill regulator is used to limit max. temperature source.

Room thermostat

Coffee room thermostat-clock for regulation temperature separate room used to thermoelectric servo (2 – position). Heating: setting thermoelectric actuators (2 – position). Lowering the temperature may using an external timer (No. 115 25 51/52 to 230 V. Cooling: Setup thermoelectric actuators (2 – position) with no power is open. “Region setting, you can restrict the hidden clips.

Room thermostat controlling the air

The room thermostat controlling the air, is used to regulate the temperature separate premises used to transform signal and thermoelectric servo (2 – position). With switch for heating and cooling. With the switch to operate in automatic mode (in this case, a room thermostat-clock control over the air), day treatment, with night setback. Setting range 5-30C. Tuning range can limit the hidden restrictive elements.

Room thermostat-clock control over the air

Room thermostat-clock control over the air, is used to regulate the temperature separate premises, used with transformation signal and thermoelectric servo (2 – position). Functions: heating and cooling. The temperature control is carried out by built-in clock. Switching time and necessary temperature can be adjusted individually. Room thermostat-clock is the manager for other thermostats. Setting range 5-40C

Use a circulating pump

Circulator – a specially mounted pump, which instantly produces an internal air in difficult circumstances.

What is the circulation pump

Circulator – a specially mounted pump, which instantly produces an internal air in difficult circumstances.

Use a circulating pump

Circulating pump – an important element of modern heating systems. Its application allows you to make better use of energy expended on heating the building. This is because, firstly, there is no need for a strong heating of the coolant required for circuits with natural circulation. Today, for example, are widely used system, where the temperature in the supply pipeline is maintained at 55oS. Secondly, there is an additional opportunity to adjust the flow of heat, depending on the need for it. In addition, the pump reduces the cost of the scheme as a whole, since it provides an opportunity to use pipe smaller than with the natural circulation diameter.

These circulators appeared some time ago, in the early 1950′s. In countries with decentralized heat they were very popular.

How does the circulator

The rotor of the circulating pump with the impeller immersed in the pumped medium. The fluid lubricates the bearings of the shaft and simultaneously cools the engine. Tightness of the engine parts, which is under stress, provides a dividing glass, made of stainless steel. The rotor shaft is often made of ceramics bearings – ceramic or graphite. The body pumps for heating systems in most cases, cast iron. For hot water, as a rule, apply the model with bronze or brass case.

Pumps of this type is practically noiseless and can operate for years without maintenance. Their installation, repair and replacement do not require labor-intensive operations, such as centering.

Technology development circulators

One of the ways to improve pumps like Taco Pump or Grundfos Pump was the union of its parts in blocks to facilitate their replacement. Such a unit can be easily disassembled into five modules: a pump casing, impeller, shaft bearings and the rotor, forming a single block in the cartouche, the motor housing with the stator, the terminal box.


pex